Since the introduction of Fentanyl as a legitimate medication, UCT has been at the forefront of assisting forensic toxicology facilities with the finest solid-phase extraction (SPE) sorbents and methodologies to extract and concentrate the drugs efficiently. With the recent emergence of newer potent analogs in the illicit community, UCT has expanded upon its existing sample preparation methods to include these novel, structurally similar derivatives. In a new paper authored by E.N.Shoff et al., published in Journal of Analytical Toxicology (doi: 10.1093/jat/bkx041), the determination of fentanyl analogs and other opioids in postmortem cases is thoroughly detailed employing Clean Screen® DAU solid-phase extraction cartridges as an integral part of this methodology.

The Miami-Dade County Medical Examiner (MDCME) Department have been experiencing an uptick in the number of opioid-related deaths since 2013.  A lot of their cases coincided with the introduction of fentanyl into the local heroin supply. This facility experienced a near 600% increase in fentanyl-related deaths in the period 2014-15, followed by an additional 200% increase in 2016.  The MDCME identified two novel fentanyl analogs in 2015 medical examiner cases: beta-hydroxythiofentanyl and acetyl fentanyl. In 2016, four additional fentanyl analogs emerged: para-fluoroisobutyryl fentanyl, butyryl fentanyl, furanyl fentanyl and carfentanil, as well as the synthetic opioid U-47700. The MDCME developed and validated a method to identify 44 opioid-related and analgesic compounds in postmortem samples using ultra high- performance liquid chromatography ion trap mass spectrometry in addition to Clean Screen® DAU for purification/concentration of post mortem blood. This sorbent produced clean extracts with high recoveries. The limit of detection for all compounds ranged from 0.1 to 5 ng/mL.

In the period of study, blood, urine, liver and/or brain specimens from approximately 500 postmortem cases were submitted for analysis based on case history and/or initial screening results. Of those cases, 375 were positive for illicit fentanyl and/or one or more fentanyl analogs. Due to the potency of these compounds, they were almost always included in the cause of death. Worth emphasizing and extremely alarming is the detection of carfentanil in 134 cases, 104 of which were initially missed by GC-MS screening. By incorporating this sensitive, highly specific, and evolving screening procedure into the workflow, toxicology laboratories continue to effectively assist the medical examiners in determining the cause and manner of death of decedents. This paper demonstrates why forensic toxicologists challenged by new fentanyl/opioid analogs turn to UCT for the finest in SPE sorbents. For more information regarding Clean Screen® sorbents, applications and methods please visit https://sampleprep.unitedchem.com/products/spe/clinical-forensic/clean-screen-dau.

Similar Posts

  • UCT QuEChERS Extraction Salts Cited In PFASs Study

    Per- and polyfluoroalkyl substances (PFASs) are widely used in the manufacturing of various industrial and consumer products including nonstick food packaging, stain repellents and aqueous film-forming foams. In a recent paper published in Chemosphere ( (2018) 199 168-173) by Adcharee Karnjanapiboonwong et al., UCT’s QuEChERS extraction salts (4,000 mg MgSO4/1,000 mg NaCl) were employed to extract PFAS and other carboxylic acid compounds from earthworms. This was the first study on earthworms in PFAS-spiked soil at background concentrations. It was found that PFASs can be detected in earthworms even in the 0.1 mg kg1 soil treatment after 21-day exposure.

  • UCT Consumables Cited in Mephedrone Study

    In a study published in Drug Testing and Analysis, J. Czerwinska et al., (doi: 10.1002/dta.2525), developed a liquid chromatography tandem mass spectrometry method using UCT’s Selectra® PFPP LC column for the simultaneous quantification of mephedrone and five of its phase I in human whole blood after extraction with UCT’s Xtrackt® solid phase extraction (SPE) columns. Mephedrone’s stability in whole blood has been previously investigated but this is the first-time stability of its metabolites has been assessed, indicating -20°C to be the recommended storage condition for all analytes.

  • UCT PSA Sorbent Cited in Sulfonamides and Trimethoprim Fish Analysis Paper

    Brazil is one of the largest veterinary markets in the world, and aquaculture, in particular fish farming, is the fastest growing sector of animal food production in the country. In fish farming, antimicrobials, including sulfonamides, are used for the treatment of bacterial diseases. Sulfonamides belong to an important group of synthetic antimicrobial agents that have been used in human and veterinary medicine for over 60 years. Recently, these drugs have been extensively employed in animals intended to produce food for human consumption.

    In a recent paper authored by Katia Nunes et al., published in Journal of Analytical Methods in Chemistry (doi.org/10.1155/2018/4506754), a multiresidue method for detecting and quantifying sulfonamides (sulfapyridine, sulfamerazine, sulfathiazole, sulfamethazine, sulfadimethoxine, sulfamethoxazole, and sulfamethoxypyridazine) and trimethoprim in tilapia fillet (Oreochromis niloticus) was developed and validated using UCT’s QuEChERS clean-up products in conjunction with liquid chromatography- mass spectrometry (LC-MS/MS). 

  • |

    6PPD, Salmon, and Tires

    You probably know what salmon and tires are, but have you ever heard of 6PPD? How about 6PPD-q? 6PPD stands for N-(1,3-dimethylbutyl)-N’-phenyl-p-phenylenediamine. When this compound is exposed to air, ozone reacts with 6PPD to form its quinone, 6PPD-q. How about salmon and tires? 6PPD is a tire stabilizer that prevents tires from breaking down. As…

  • UCT’s ChloroFiltr® cited in Agrochemical Paper

    UCT is recognized around the world as the first company to commercialize the use of the QuEChERS technique for use in pesticide and herbicide analysis. While supplying a large diversity of commonly available clean-up sorbents, UCT is sole supplier of ChloroFiltr®, a novel polymeric based sorbent designed for the removal of chlorophyll from acetonitrile extracts without compromising on the recovery of planer pesticides.

    In a recent paper published in Environmental Science and Technology Letters by E.M.Peterson et al., (DOI: 10.1021/acs.estlett.7b00123), ChloroFiltr®  is put to use for the analysis of neonicotinoids on wildflowers close in proximity to cattle feed yards. 

  • UCT Clean Screen® Sorbent Cited in Carfentanil Study

    Carfentanil (methyl 1-(2-phenylethyl)-4-[phenyl(propanoyl)amino]piperidine-4- carboxylate) is the most potent opioid used commercially with a quantitative potency approximately 10,000 times that of morphine and 100 times that of fentanyl. The drug is marketed under the trade name ‘Wildnil’ as a general anesthetic agent for large animals. Like its analogue fentanyl, Carfentanil is lipophilic and will readily and…