“Selectra® DA 100 x 4.6 mm x 3 µm” has been added to your cart.
View cart
Showing 81–120 of 138 results
-

$531.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$552.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 150 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$545.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 150 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$571.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 250 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® C8 guard cartridge packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching C8 selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$163.00
SELECTRA® C8 guard cartridge packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching C8 selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$654.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$475.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$463.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$478.00
SELECTRA® C8 reversed-phase column packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, offering similar selectivity to C18 for non-polar compounds with reduced hydrophobic retention. Fully endcapped with excellent carbon loading, it is ideal for applications requiring shorter retention, faster elution, or alternative selectivity compared to traditional C18 columns.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® C8 guard cartridge packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching C8 selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$176.00
SELECTRA® C8 guard cartridge packed with high-purity, fully porous type B silica and bonded octyl (C8) phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching C8 selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$792.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$531.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$490.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$807.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 4.6 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$531.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$490.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

-

-

-

$557.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 150 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$585.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 250 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® DA guard cartridge packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching DA selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® DA guard cartridge packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching DA selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$706.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$490.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$450.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$719.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 4.6 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$490.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 4.6 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$450.00
SELECTRA® DA reversed-phase column packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, offering enhanced retention and selectivity for aromatic and moderately polar analytes. Designed for compounds that are difficult to retain or resolve on traditional C18 phases, it is ideal for therapeutic drugs, drugs of abuse, pesticides, mycotoxins, and related applications in forensic, environmental, food, and pharmaceutical analysis.
Key Specifications
- Quantity: Each
- Dimensions: 50 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® DA guard cartridge packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching DA selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 4.6 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$132.00
SELECTRA® DA guard cartridge packed with high-purity, fully porous type B silica and a unique polyaromatic stationary phase, designed to protect the analytical column from particulates and strongly retained contaminants while maintaining matching DA selectivity and retention characteristics.
Key Specifications
- Quantity: 2
- Dimensions: 10 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

-

-

$128.00
Guard Cartridge (2/pack)
*Requires SLGRDHLDR Guard Cartridge Holder
10 x 2.1mm
HPLC column
-

-

$807.00
SELECTRA® PFPP reversed-phase column packed with high-purity, fully porous type B silica and bonded pentafluorophenylpropyl (PFPP) phase, offering unique selectivity through hydrophobic, dipole-dipole, hydrogen bonding, and π-π interactions. Suitable for reverse-phase, normal-phase, and HILIC separations, it provides enhanced retention for aromatic, halogenated, and polar analytes. Ideal for food, environmental, forensic, and pharmaceutical applications.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 1.8 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 1030 bar (15,000 psi)
Documentation
-

$611.00
SELECTRA® PFPP reversed-phase column packed with high-purity, fully porous type B silica and bonded pentafluorophenylpropyl (PFPP) phase, offering unique selectivity through hydrophobic, dipole-dipole, hydrogen bonding, and π-π interactions. Suitable for reverse-phase, normal-phase, and HILIC separations, it provides enhanced retention for aromatic, halogenated, and polar analytes. Ideal for food, environmental, forensic, and pharmaceutical applications.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 3 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation
-

$563.00
SELECTRA® PFPP reversed-phase column packed with high-purity, fully porous type B silica and bonded pentafluorophenylpropyl (PFPP) phase, offering unique selectivity through hydrophobic, dipole-dipole, hydrogen bonding, and π-π interactions. Suitable for reverse-phase, normal-phase, and HILIC separations, it provides enhanced retention for aromatic, halogenated, and polar analytes. Ideal for food, environmental, forensic, and pharmaceutical applications.
Key Specifications
- Quantity: Each
- Dimensions: 100 mm x 2.1 mm
- Particle Size: 5 µm
- Pore Size: 100 Å
- pH Range: 2–8
- Max Temperature: 60°C
- Max Pressure: 275 bar (4,000 psi)
Documentation